diff options
| author | Christoph Berg <myon@debian.org> | 2026-04-07 19:02:45 +0200 |
|---|---|---|
| committer | Christoph Berg <myon@debian.org> | 2026-04-07 19:02:45 +0200 |
| commit | f647d78463c1250ce9c99af664615fafccf5e959 (patch) | |
| tree | 5b00428cef68aef1c9d407e2d4535687422419b6 /doc/user_guide/en/tutorial-wide-graph-settings.adoc | |
| parent | 0a13f1fdb9928b6d012569dd65f7f6ef18fac2f8 (diff) | |
New upstream version 3.0.0upstream/3.0.0
Diffstat (limited to 'doc/user_guide/en/tutorial-wide-graph-settings.adoc')
| -rw-r--r--[-rwxr-xr-x] | doc/user_guide/en/tutorial-wide-graph-settings.adoc | 100 |
1 files changed, 50 insertions, 50 deletions
diff --git a/doc/user_guide/en/tutorial-wide-graph-settings.adoc b/doc/user_guide/en/tutorial-wide-graph-settings.adoc index 618d2970..626bc893 100755..100644 --- a/doc/user_guide/en/tutorial-wide-graph-settings.adoc +++ b/doc/user_guide/en/tutorial-wide-graph-settings.adoc @@ -1,50 +1,50 @@ -// Status=review
-
-The WSJT-X Wide Graph window displays the frequency spectrum of
-received audio. Usually, the upper portion shows a waterfall plot of
-the frequency spectrum (a spectrogram) and a line plot of the current
-or average spectrum. Controls at the bottom of the window are used to
-set up the displayed audio frequency range, color palette, and scaling
-of the spectrum displays. A control *Spec nn%* at the bottom right
-lets you adjust the vertical fraction of the window occupied by the
-spectrum line plot. It is important to set appropriate lower and
-upper audio frequency limits for the Wide Graph because these limits
-define the FT8 decoder's search window. For this tutorial, the limits
-will be set to cover 100-3300 Hz:
-
-- Set *Start* = 100 Hz.
-
-- Set *Bins/Pixel* = 5. Smaller or larger values make the Wide Graph
-cover a smaller/larger frequency range.
-
-- Use the mouse to grab the left or right edge of the *Wide Graph*,
-and adjust its width so that the upper frequency limit is about 3300
-Hz.
-
-- Set *N Avg* = 2. This number determines how many spectra are
-averaged to produce each line in the spectrogram. Smaller values make
-the spectrogram scroll and update more frequently, resulting in
-signals being more spread out in the vertical (time) direction. Larger
-values make it easier to detect very weak signals.
-
-The *Palette* setting controls the color scheme used for the spectrogram:
-
-- Set *Palette* = Fldigi
-
-When *Flatten* is checked, _WSJT-X_ attempts to correct for slope or
-curvature in the receiver's passband shape.
-
-- *Flatten* = checked
-
-The line plot can be set to display the current (un-averaged) spectrum or the cumulative (averaged)
-spectrum:
-
-- Select *Cumulative* for data display
-- Set the *Gain* and *Zero* sliders for the waterfall and spectrum to near midscale
-
-The *Spec nn%* setting determines what fraction of the vertical extent of the Wide Graph will
-be used for the line plot of the spectrum. Setting *Spec* to 0 will eliminate the line plot and
-a setting of 100 will eliminate the spectrogram and show only the line plot:
-
-- Set *Spec* = 50%
-
+// Status=review + +The WSJT-X Wide Graph window displays the frequency spectrum of +received audio. Usually, the upper portion shows a waterfall plot of +the frequency spectrum (a spectrogram) and a line plot of the current +or average spectrum. Controls at the bottom of the window are used to +set up the displayed audio frequency range, color palette, and scaling +of the spectrum displays. A control *Spec nn%* at the bottom right +lets you adjust the vertical fraction of the window occupied by the +spectrum line plot. It is important to set appropriate lower and +upper audio frequency limits for the Wide Graph because these limits +define the FT8 decoder's search window. For this tutorial, the limits +will be set to cover 100-3300 Hz: + +- Set *Start* = 100 Hz. + +- Set *Bins/Pixel* = 5. Smaller or larger values make the Wide Graph +cover a smaller/larger frequency range. + +- Use the mouse to grab the left or right edge of the *Wide Graph*, +and adjust its width so that the upper frequency limit is about 3300 +Hz. + +- Set *N Avg* = 2. This number determines how many spectra are +averaged to produce each line in the spectrogram. Smaller values make +the spectrogram scroll and update more frequently, resulting in +signals being more spread out in the vertical (time) direction. Larger +values make it easier to detect very weak signals. + +The *Palette* setting controls the color scheme used for the spectrogram: + +- Set *Palette* = Fldigi + +When *Flatten* is checked, _WSJT-X_ attempts to correct for slope or +curvature in the receiver's passband shape. + +- *Flatten* = checked + +The line plot can be set to display the current (un-averaged) spectrum or the cumulative (averaged) +spectrum: + +- Select *Cumulative* for data display +- Set the *Gain* and *Zero* sliders for the waterfall and spectrum to near midscale + +The *Spec nn%* setting determines what fraction of the vertical extent of the Wide Graph will +be used for the line plot of the spectrum. Setting *Spec* to 0 will eliminate the line plot and +a setting of 100 will eliminate the spectrogram and show only the line plot: + +- Set *Spec* = 50% + |
