From f647d78463c1250ce9c99af664615fafccf5e959 Mon Sep 17 00:00:00 2001 From: Christoph Berg Date: Tue, 7 Apr 2026 19:02:45 +0200 Subject: New upstream version 3.0.0 --- doc/user_guide/en/tutorial-example5.adoc | 120 +++++++++++++++---------------- 1 file changed, 60 insertions(+), 60 deletions(-) mode change 100755 => 100644 doc/user_guide/en/tutorial-example5.adoc (limited to 'doc/user_guide/en/tutorial-example5.adoc') diff --git a/doc/user_guide/en/tutorial-example5.adoc b/doc/user_guide/en/tutorial-example5.adoc old mode 100755 new mode 100644 index e49ec561..b51e032f --- a/doc/user_guide/en/tutorial-example5.adoc +++ b/doc/user_guide/en/tutorial-example5.adoc @@ -1,60 +1,60 @@ -Do not confuse FST4 with FT4, which has a very different purpose! -FST4 is designed primarily for making weak-signal 2-way QSOs on the LF -and MF bands. T/R periods from 15 s up to 1800 s are available. Longer -sequences provide better sensitivity only if Tx and Rx frequency -instability and channel Doppler spread are small enough that received -signals will remain phase coherent over periods spanning several -transmitted symbols. Generally speaking, Rx and Tx frequency changes -during the transmission and channel Doppler spread should each be -small compared to the symbol keying rate. (See <> in -the Protocol Specifications section.) For example, the keying rate -for FST4-1800 is 0.089 Baud, so successful operation requires frequency -stability to be better than (and Doppler Spread less than) around 0.05 Hz. - -Operation with FST4 is similar to that with other _WSJT-X_ modes. Most -on-screen controls, auto-sequencing, and other features behave in -familiar ways. However, operating conventions on the 2200 and 630 m -bands have made some additional user controls desirable. Spin boxes -labeled *F Low* and *F High* set lower and upper frequency limits used -by the FST4 decoder, and these limits are marked by dark green -angle-bracket symbols *< >* on the Wide Graph frequency scale: - -image::FST4_Decoding_Limits.png[align="center"] - -{empty} + - -image::FST4_center.png[align="center"] - -It's best to keep the decoding range fairly small, since QRM and -transmissions in other modes or sequence lengths will slow down the -decoding process (and of course will be undecodable). By checking -*Single decode* on the *File | Settings | General* tab, you can -further limit the decoding range to the setting of *F Tol* on -either side of *Rx Freq*. - -A noise blanker can be enabled by setting the *NB* percentage to a -non-zero value. (This control is located just above the input level -thermometer.) The *NB* setting determines how many of the -largest-amplitude samples will be blanked (zeroed) before the data is -submitted to the decoder. Most users find that settings between 0% (no -blanking) and 10% work best. If the noise blanker percentage is set to --1%, then the decoder will try 0, 5, 10, 15, and 20 % in -succession. Similarly, a setting of -2% causes the decoder to loop -over blanking percentages 0, 2, 4, ... 20 %. To save time, the -multiple blanking percentages triggered by negative *NB* settings are -tried only for signal candidates located near (within +/- 20 Hz) of -the *Rx* frequency setting. - -.Open a sample Wave File: - -- Select *FST4* on the *Mode* menu. Set *T/R* to 60 s and *Decode | Deep*. -- Set *NB* (noise blanker) to 0%. -- Set up the Wide Graph display with settings appropriate for the FST4-60 mode. -For example, try *Bins/Pixel* 2 and *N Avg* 4. Set the *Start* frequency and the width of -the Wide Graph to include the frequency range that you want to decode. For this -example, make sure that *Start* is less than 1000 Hz and that the Wide Graph extends to above 1400 Hz. -- Set *F Low* 1000, *F High* 1400. These settings define the decoder's frequency search range. -- Open a sample Wave file using *File | Open* and select the file -...\save\samples\FST4+FST4W\210115_0058.wav. After _WSJT-X_ has processed the file you should see something similar to the following screen shot: - -image::FST4-1.png[align="left"] +Do not confuse FST4 with FT4, which has a very different purpose! +FST4 is designed primarily for making weak-signal 2-way QSOs on the LF +and MF bands. T/R periods from 15 s up to 1800 s are available. Longer +sequences provide better sensitivity only if Tx and Rx frequency +instability and channel Doppler spread are small enough that received +signals will remain phase coherent over periods spanning several +transmitted symbols. Generally speaking, Rx and Tx frequency changes +during the transmission and channel Doppler spread should each be +small compared to the symbol keying rate. (See <> in +the Protocol Specifications section.) For example, the keying rate +for FST4-1800 is 0.089 Baud, so successful operation requires frequency +stability to be better than (and Doppler Spread less than) around 0.05 Hz. + +Operation with FST4 is similar to that with other _WSJT-X_ modes. Most +on-screen controls, auto-sequencing, and other features behave in +familiar ways. However, operating conventions on the 2200 and 630 m +bands have made some additional user controls desirable. Spin boxes +labeled *F Low* and *F High* set lower and upper frequency limits used +by the FST4 decoder, and these limits are marked by dark green +angle-bracket symbols *< >* on the Wide Graph frequency scale: + +image::FST4_Decoding_Limits.png[align="center"] + +{empty} + + +image::FST4_center.png[align="center"] + +It's best to keep the decoding range fairly small, since QRM and +transmissions in other modes or sequence lengths will slow down the +decoding process (and of course will be undecodable). By checking +*Single decode* on the *File | Settings | General* tab, you can +further limit the decoding range to the setting of *F Tol* on +either side of *Rx Freq*. + +A noise blanker can be enabled by setting the *NB* percentage to a +non-zero value. (This control is located just above the input level +thermometer.) The *NB* setting determines how many of the +largest-amplitude samples will be blanked (zeroed) before the data is +submitted to the decoder. Most users find that settings between 0% (no +blanking) and 10% work best. If the noise blanker percentage is set to +-1%, then the decoder will try 0, 5, 10, 15, and 20 % in +succession. Similarly, a setting of -2% causes the decoder to loop +over blanking percentages 0, 2, 4, ... 20 %. To save time, the +multiple blanking percentages triggered by negative *NB* settings are +tried only for signal candidates located near (within +/- 20 Hz) of +the *Rx* frequency setting. + +.Open a sample Wave File: + +- Select *FST4* on the *Mode* menu. Set *T/R* to 60 s and *Decode | Deep*. +- Set *NB* (noise blanker) to 0%. +- Set up the Wide Graph display with settings appropriate for the FST4-60 mode. +For example, try *Bins/Pixel* 2 and *N Avg* 4. Set the *Start* frequency and the width of +the Wide Graph to include the frequency range that you want to decode. For this +example, make sure that *Start* is less than 1000 Hz and that the Wide Graph extends to above 1400 Hz. +- Set *F Low* 1000, *F High* 1400. These settings define the decoder's frequency search range. +- Open a sample Wave file using *File | Open* and select the file +...\save\samples\FST4+FST4W\210115_0058.wav. After _WSJT-X_ has processed the file you should see something similar to the following screen shot: + +image::FST4-1.png[align="left"] -- cgit v1.2.3