diff options
| author | Christoph Berg <myon@debian.org> | 2025-01-09 22:12:06 +0100 |
|---|---|---|
| committer | Christoph Berg <myon@debian.org> | 2025-01-09 22:12:06 +0100 |
| commit | 992d4b4b8d3f3a630a2cf00d593ee4ce4dfa7ce8 (patch) | |
| tree | fbfdfe6bcb0a8a114be2480dac53d88c977e4869 /doc/user_guide/en/tutorial-wide-graph-settings.adoc | |
| parent | 4320ce238aae1fe87fc9f379cdd816e9317885fa (diff) | |
New upstream version 2.7.0~rc8+repackupstream/2.7.0_rc8+repack
Diffstat (limited to 'doc/user_guide/en/tutorial-wide-graph-settings.adoc')
| -rwxr-xr-x | doc/user_guide/en/tutorial-wide-graph-settings.adoc | 92 |
1 files changed, 46 insertions, 46 deletions
diff --git a/doc/user_guide/en/tutorial-wide-graph-settings.adoc b/doc/user_guide/en/tutorial-wide-graph-settings.adoc index 6f2dcd47..4d4db8bb 100755 --- a/doc/user_guide/en/tutorial-wide-graph-settings.adoc +++ b/doc/user_guide/en/tutorial-wide-graph-settings.adoc @@ -1,46 +1,46 @@ -// Status=review
-
-The WSJT-X Wide Graph window displays the frequency spectrum of the received audio. Usually, the
-upper portion of the window shows a waterfall plot of the frequency spectrum (a spectrogram) and
-a line plot of the current or average spectrum. Controls at the bottom of the window are used to
-set up the displayed audio frequency range, color palette, and scaling of the spectrum displays.
-A control on the bottom right of the Wide Graph (displayed as *Spec nn%*) lets you control
-the vertical fraction of the window occupied by the spectrum line plot.
-It is important to set appropriate lower and upper
-audio frequency limits for the Wide Graph because these limits define the FT8 decoder's search window.
-For this tutorial, the limits will be set to cover 100-3300 Hz:
-
-- Set *Start* = 100 Hz.
-- Set *Bins/Pixel* = 5. Smaller/larger values make the Wide Graph cover a smaller/larger
-frequency range.
-- Use the mouse to grab the left or right edge of the *Wide Graph*, and
-adjust its width so that the upper frequency limit is about 3300 Hz.
-
-The *N Avg* setting controls how many spectra are averaged to produce each line in the spectrogram.
-Smaller values make the spectrogram update more frequently, resulting in signals being more spread
-out in the vertical (time) direction.
-On the other hand, larger values make it easier to detect very weak signals:
-
-- Set *N Avg* = 2.
-
-The *Palette* setting controls the color scheme used for the spectrogram:
-
-- Set *Palette* = Fldigi
-
-When *Flatten* is checked, WSJT-X attempts to correct for slope or curvature in the receiver's
-passband shape.
-
-- *Flatten* = checked
-
-The line plot can be set to display the current (un-averaged) spectrum or the cumulative (averaged)
-spectrum:
-
-- Select *Cumulative* for data display
-- Set the *Gain* and *Zero* sliders for the waterfall and spectrum to near midscale
-
-The *Spec nn%* setting determines what fraction of the vertical extent of the Wide Graph will
-be used for the line plot of the spectrum. Setting *Spec* to 0 will eliminate the line plot and
-a setting of 100 will eliminate the spectrogram and show only the line plot:
-
-- Set *Spec* = 50%
-
+// Status=review + +The WSJT-X Wide Graph window displays the frequency spectrum of the received audio. Usually, the +upper portion of the window shows a waterfall plot of the frequency spectrum (a spectrogram) and +a line plot of the current or average spectrum. Controls at the bottom of the window are used to +set up the displayed audio frequency range, color palette, and scaling of the spectrum displays. +A control on the bottom right of the Wide Graph (displayed as *Spec nn%*) lets you control +the vertical fraction of the window occupied by the spectrum line plot. +It is important to set appropriate lower and upper +audio frequency limits for the Wide Graph because these limits define the FT8 decoder's search window. +For this tutorial, the limits will be set to cover 100-3300 Hz: + +- Set *Start* = 100 Hz. +- Set *Bins/Pixel* = 5. Smaller/larger values make the Wide Graph cover a smaller/larger +frequency range. +- Use the mouse to grab the left or right edge of the *Wide Graph*, and +adjust its width so that the upper frequency limit is about 3300 Hz. + +The *N Avg* setting controls how many spectra are averaged to produce each line in the spectrogram. +Smaller values make the spectrogram update more frequently, resulting in signals being more spread +out in the vertical (time) direction. +On the other hand, larger values make it easier to detect very weak signals: + +- Set *N Avg* = 2. + +The *Palette* setting controls the color scheme used for the spectrogram: + +- Set *Palette* = Fldigi + +When *Flatten* is checked, WSJT-X attempts to correct for slope or curvature in the receiver's +passband shape. + +- *Flatten* = checked + +The line plot can be set to display the current (un-averaged) spectrum or the cumulative (averaged) +spectrum: + +- Select *Cumulative* for data display +- Set the *Gain* and *Zero* sliders for the waterfall and spectrum to near midscale + +The *Spec nn%* setting determines what fraction of the vertical extent of the Wide Graph will +be used for the line plot of the spectrum. Setting *Spec* to 0 will eliminate the line plot and +a setting of 100 will eliminate the spectrogram and show only the line plot: + +- Set *Spec* = 50% + |
