summaryrefslogtreecommitdiff
path: root/doc/user_guide/en/tutorial-wide-graph-settings.adoc
diff options
context:
space:
mode:
authorChristoph Berg <myon@debian.org>2025-01-09 22:12:06 +0100
committerChristoph Berg <myon@debian.org>2025-01-09 22:12:06 +0100
commit992d4b4b8d3f3a630a2cf00d593ee4ce4dfa7ce8 (patch)
treefbfdfe6bcb0a8a114be2480dac53d88c977e4869 /doc/user_guide/en/tutorial-wide-graph-settings.adoc
parent4320ce238aae1fe87fc9f379cdd816e9317885fa (diff)
New upstream version 2.7.0~rc8+repackupstream/2.7.0_rc8+repack
Diffstat (limited to 'doc/user_guide/en/tutorial-wide-graph-settings.adoc')
-rwxr-xr-xdoc/user_guide/en/tutorial-wide-graph-settings.adoc92
1 files changed, 46 insertions, 46 deletions
diff --git a/doc/user_guide/en/tutorial-wide-graph-settings.adoc b/doc/user_guide/en/tutorial-wide-graph-settings.adoc
index 6f2dcd47..4d4db8bb 100755
--- a/doc/user_guide/en/tutorial-wide-graph-settings.adoc
+++ b/doc/user_guide/en/tutorial-wide-graph-settings.adoc
@@ -1,46 +1,46 @@
-// Status=review
-
-The WSJT-X Wide Graph window displays the frequency spectrum of the received audio. Usually, the
-upper portion of the window shows a waterfall plot of the frequency spectrum (a spectrogram) and
-a line plot of the current or average spectrum. Controls at the bottom of the window are used to
-set up the displayed audio frequency range, color palette, and scaling of the spectrum displays.
-A control on the bottom right of the Wide Graph (displayed as *Spec nn%*) lets you control
-the vertical fraction of the window occupied by the spectrum line plot.
-It is important to set appropriate lower and upper
-audio frequency limits for the Wide Graph because these limits define the FT8 decoder's search window.
-For this tutorial, the limits will be set to cover 100-3300 Hz:
-
-- Set *Start* = 100 Hz.
-- Set *Bins/Pixel* = 5. Smaller/larger values make the Wide Graph cover a smaller/larger
-frequency range.
-- Use the mouse to grab the left or right edge of the *Wide Graph*, and
-adjust its width so that the upper frequency limit is about 3300 Hz.
-
-The *N Avg* setting controls how many spectra are averaged to produce each line in the spectrogram.
-Smaller values make the spectrogram update more frequently, resulting in signals being more spread
-out in the vertical (time) direction.
-On the other hand, larger values make it easier to detect very weak signals:
-
-- Set *N Avg* = 2.
-
-The *Palette* setting controls the color scheme used for the spectrogram:
-
-- Set *Palette* = Fldigi
-
-When *Flatten* is checked, WSJT-X attempts to correct for slope or curvature in the receiver's
-passband shape.
-
-- *Flatten* = checked
-
-The line plot can be set to display the current (un-averaged) spectrum or the cumulative (averaged)
-spectrum:
-
-- Select *Cumulative* for data display
-- Set the *Gain* and *Zero* sliders for the waterfall and spectrum to near midscale
-
-The *Spec nn%* setting determines what fraction of the vertical extent of the Wide Graph will
-be used for the line plot of the spectrum. Setting *Spec* to 0 will eliminate the line plot and
-a setting of 100 will eliminate the spectrogram and show only the line plot:
-
-- Set *Spec* = 50%
-
+// Status=review
+
+The WSJT-X Wide Graph window displays the frequency spectrum of the received audio. Usually, the
+upper portion of the window shows a waterfall plot of the frequency spectrum (a spectrogram) and
+a line plot of the current or average spectrum. Controls at the bottom of the window are used to
+set up the displayed audio frequency range, color palette, and scaling of the spectrum displays.
+A control on the bottom right of the Wide Graph (displayed as *Spec nn%*) lets you control
+the vertical fraction of the window occupied by the spectrum line plot.
+It is important to set appropriate lower and upper
+audio frequency limits for the Wide Graph because these limits define the FT8 decoder's search window.
+For this tutorial, the limits will be set to cover 100-3300 Hz:
+
+- Set *Start* = 100 Hz.
+- Set *Bins/Pixel* = 5. Smaller/larger values make the Wide Graph cover a smaller/larger
+frequency range.
+- Use the mouse to grab the left or right edge of the *Wide Graph*, and
+adjust its width so that the upper frequency limit is about 3300 Hz.
+
+The *N Avg* setting controls how many spectra are averaged to produce each line in the spectrogram.
+Smaller values make the spectrogram update more frequently, resulting in signals being more spread
+out in the vertical (time) direction.
+On the other hand, larger values make it easier to detect very weak signals:
+
+- Set *N Avg* = 2.
+
+The *Palette* setting controls the color scheme used for the spectrogram:
+
+- Set *Palette* = Fldigi
+
+When *Flatten* is checked, WSJT-X attempts to correct for slope or curvature in the receiver's
+passband shape.
+
+- *Flatten* = checked
+
+The line plot can be set to display the current (un-averaged) spectrum or the cumulative (averaged)
+spectrum:
+
+- Select *Cumulative* for data display
+- Set the *Gain* and *Zero* sliders for the waterfall and spectrum to near midscale
+
+The *Spec nn%* setting determines what fraction of the vertical extent of the Wide Graph will
+be used for the line plot of the spectrum. Setting *Spec* to 0 will eliminate the line plot and
+a setting of 100 will eliminate the spectrogram and show only the line plot:
+
+- Set *Spec* = 50%
+