summaryrefslogtreecommitdiff
path: root/doc/user_guide/en/tutorial-example5.adoc
diff options
context:
space:
mode:
Diffstat (limited to 'doc/user_guide/en/tutorial-example5.adoc')
-rw-r--r--[-rwxr-xr-x]doc/user_guide/en/tutorial-example5.adoc120
1 files changed, 60 insertions, 60 deletions
diff --git a/doc/user_guide/en/tutorial-example5.adoc b/doc/user_guide/en/tutorial-example5.adoc
index e49ec561..b51e032f 100755..100644
--- a/doc/user_guide/en/tutorial-example5.adoc
+++ b/doc/user_guide/en/tutorial-example5.adoc
@@ -1,60 +1,60 @@
-Do not confuse FST4 with FT4, which has a very different purpose!
-FST4 is designed primarily for making weak-signal 2-way QSOs on the LF
-and MF bands. T/R periods from 15 s up to 1800 s are available. Longer
-sequences provide better sensitivity only if Tx and Rx frequency
-instability and channel Doppler spread are small enough that received
-signals will remain phase coherent over periods spanning several
-transmitted symbols. Generally speaking, Rx and Tx frequency changes
-during the transmission and channel Doppler spread should each be
-small compared to the symbol keying rate. (See <<SLOW_TAB,Table 7>> in
-the Protocol Specifications section.) For example, the keying rate
-for FST4-1800 is 0.089 Baud, so successful operation requires frequency
-stability to be better than (and Doppler Spread less than) around 0.05 Hz.
-
-Operation with FST4 is similar to that with other _WSJT-X_ modes. Most
-on-screen controls, auto-sequencing, and other features behave in
-familiar ways. However, operating conventions on the 2200 and 630 m
-bands have made some additional user controls desirable. Spin boxes
-labeled *F Low* and *F High* set lower and upper frequency limits used
-by the FST4 decoder, and these limits are marked by dark green
-angle-bracket symbols *< >* on the Wide Graph frequency scale:
-
-image::FST4_Decoding_Limits.png[align="center"]
-
-{empty} +
-
-image::FST4_center.png[align="center"]
-
-It's best to keep the decoding range fairly small, since QRM and
-transmissions in other modes or sequence lengths will slow down the
-decoding process (and of course will be undecodable). By checking
-*Single decode* on the *File | Settings | General* tab, you can
-further limit the decoding range to the setting of *F Tol* on
-either side of *Rx Freq*.
-
-A noise blanker can be enabled by setting the *NB* percentage to a
-non-zero value. (This control is located just above the input level
-thermometer.) The *NB* setting determines how many of the
-largest-amplitude samples will be blanked (zeroed) before the data is
-submitted to the decoder. Most users find that settings between 0% (no
-blanking) and 10% work best. If the noise blanker percentage is set to
--1%, then the decoder will try 0, 5, 10, 15, and 20 % in
-succession. Similarly, a setting of -2% causes the decoder to loop
-over blanking percentages 0, 2, 4, ... 20 %. To save time, the
-multiple blanking percentages triggered by negative *NB* settings are
-tried only for signal candidates located near (within +/- 20 Hz) of
-the *Rx* frequency setting.
-
-.Open a sample Wave File:
-
-- Select *FST4* on the *Mode* menu. Set *T/R* to 60 s and *Decode | Deep*.
-- Set *NB* (noise blanker) to 0%.
-- Set up the Wide Graph display with settings appropriate for the FST4-60 mode.
-For example, try *Bins/Pixel* 2 and *N Avg* 4. Set the *Start* frequency and the width of
-the Wide Graph to include the frequency range that you want to decode. For this
-example, make sure that *Start* is less than 1000 Hz and that the Wide Graph extends to above 1400 Hz.
-- Set *F Low* 1000, *F High* 1400. These settings define the decoder's frequency search range.
-- Open a sample Wave file using *File | Open* and select the file
-...\save\samples\FST4+FST4W\210115_0058.wav. After _WSJT-X_ has processed the file you should see something similar to the following screen shot:
-
-image::FST4-1.png[align="left"]
+Do not confuse FST4 with FT4, which has a very different purpose!
+FST4 is designed primarily for making weak-signal 2-way QSOs on the LF
+and MF bands. T/R periods from 15 s up to 1800 s are available. Longer
+sequences provide better sensitivity only if Tx and Rx frequency
+instability and channel Doppler spread are small enough that received
+signals will remain phase coherent over periods spanning several
+transmitted symbols. Generally speaking, Rx and Tx frequency changes
+during the transmission and channel Doppler spread should each be
+small compared to the symbol keying rate. (See <<SLOW_TAB,Table 7>> in
+the Protocol Specifications section.) For example, the keying rate
+for FST4-1800 is 0.089 Baud, so successful operation requires frequency
+stability to be better than (and Doppler Spread less than) around 0.05 Hz.
+
+Operation with FST4 is similar to that with other _WSJT-X_ modes. Most
+on-screen controls, auto-sequencing, and other features behave in
+familiar ways. However, operating conventions on the 2200 and 630 m
+bands have made some additional user controls desirable. Spin boxes
+labeled *F Low* and *F High* set lower and upper frequency limits used
+by the FST4 decoder, and these limits are marked by dark green
+angle-bracket symbols *< >* on the Wide Graph frequency scale:
+
+image::FST4_Decoding_Limits.png[align="center"]
+
+{empty} +
+
+image::FST4_center.png[align="center"]
+
+It's best to keep the decoding range fairly small, since QRM and
+transmissions in other modes or sequence lengths will slow down the
+decoding process (and of course will be undecodable). By checking
+*Single decode* on the *File | Settings | General* tab, you can
+further limit the decoding range to the setting of *F Tol* on
+either side of *Rx Freq*.
+
+A noise blanker can be enabled by setting the *NB* percentage to a
+non-zero value. (This control is located just above the input level
+thermometer.) The *NB* setting determines how many of the
+largest-amplitude samples will be blanked (zeroed) before the data is
+submitted to the decoder. Most users find that settings between 0% (no
+blanking) and 10% work best. If the noise blanker percentage is set to
+-1%, then the decoder will try 0, 5, 10, 15, and 20 % in
+succession. Similarly, a setting of -2% causes the decoder to loop
+over blanking percentages 0, 2, 4, ... 20 %. To save time, the
+multiple blanking percentages triggered by negative *NB* settings are
+tried only for signal candidates located near (within +/- 20 Hz) of
+the *Rx* frequency setting.
+
+.Open a sample Wave File:
+
+- Select *FST4* on the *Mode* menu. Set *T/R* to 60 s and *Decode | Deep*.
+- Set *NB* (noise blanker) to 0%.
+- Set up the Wide Graph display with settings appropriate for the FST4-60 mode.
+For example, try *Bins/Pixel* 2 and *N Avg* 4. Set the *Start* frequency and the width of
+the Wide Graph to include the frequency range that you want to decode. For this
+example, make sure that *Start* is less than 1000 Hz and that the Wide Graph extends to above 1400 Hz.
+- Set *F Low* 1000, *F High* 1400. These settings define the decoder's frequency search range.
+- Open a sample Wave file using *File | Open* and select the file
+...\save\samples\FST4+FST4W\210115_0058.wav. After _WSJT-X_ has processed the file you should see something similar to the following screen shot:
+
+image::FST4-1.png[align="left"]